1.
Rev. bras. ortop ; 53(3): 378-383, May-June 2018. graf
Article in English | LILACS | ID: biblio-959139

ABSTRACT

ABSTRACT Biapical femoral deformities are challenging to treat. In order to correct concomitant metaphyseal and diaphyseal deformities of the femur, the authors propose a double femoral controlled osteotomy with combined internal fixation, consisting of a Puddu plate and an intramedullary nail. The method was described in two patients. Results were analyzed using a visual analog scale (VAS), the Lysholm score, and SF-36. No complications were found. Complete consolidation of the osteotomies and radiographic alignment correction were achieved. Results were obtained with a minimum follow-up of 66 months. Both patients had improved for pain (VAS from 60 to 40 and from 50 to 20 at reassessment), function (Lysholm score from 78 to 93 and from 55 to 73) and quality of life (SF-36, both mental - from 40.7 to 57.1 in case one and from 24.7 to 59.7 in case two - and physical - from 27.7 to 45.6 and from 28.2 to 46.8). The authors have found that this technique is a reliable, accurate, and reproducible solution for biapical deformities of the femur.


RESUMO O tratamento das deformidades femorais biapicais é desafiador. Para a correção das deformidades metafisárias e diafisárias concomitantes do fêmur, os autores propõem uma osteotomia dupla femoral controlada com uma fixação interna combinada com uma placa de Puddu e uma haste intramedular. O método foi demonstrado em dois pacientes. Os resultados foram analisados com escala visual analógica (EVA) e os escores Lysholm e SF-36. Não foram encontradas complicações. A consolidação total das osteotomias e a correção do alinhamento radiográfico foram alcançadas. Os resultados foram obtidos com um seguimento mínimo de 66 meses. Ambos os pacientes apresentaram melhoria na dor (EVA de 60 a 40 e de 50 para 20), função (Lysholm de 78 a 93 e 55 a 73) e qualidade de vida (SF36, ambos mentais - de 40,7 a 57,1 no caso um e 24,7 a 59,7 no caso dois - e físico - de 27,7 para 45,6 e de 28,2 para 46,8). Os autores concluíram que essa técnica é uma solução confiável, precisa e reprodutível para deformidades biapicais do fêmur.


Subject(s)
Humans , Male , Female , Adult , Osteotomy , External Fixators , Joint Deformities, Acquired , Fracture Fixation, Intramedullary
2.
Acta ortop. bras ; 21(6): 315-319, 2013. ilus
Article in Portuguese | LILACS | ID: lil-689702

ABSTRACT

OBJETIVO: Analisar a experiência com transplante homologo do mecanismo extensor nas artroplastias totais do joelho e comparar resultados com experiência internacional.MÉTODOS: Foram avaliados retrospectivamente três casos de transplante homologo do mecanismo extensor após artroplastia total do joelho que foram realizados em nosso serviço com apoio de um dos poucos bancos de tecidos brasileiros e tentamos estabelecer se nossa experiência foi similar à reportada na literatura internacional quanto a indicação do paciente, técnica utilizada e resultados.RESULTADOS: Dois casos evoluíram bem com o procedimento e um caso apresentou resultado insatisfatório evoluindo para amputação. Assim como mostra a literatura, tensão adequada do enxerto, fixação tibial apropriada e principalmente seleção precisa do paciente são os melhores preditores de bom resultado.CONCLUSÃO: O procedimento em questão tem indicação precisa, apesar de incomum, tanto pela raridade da problemática quanto pela baixa demanda de enxertos devido aos poucos bancos de tecidos no Brasil.Nível de Evidência IV, Série de Casos.


OBJECTIVE: To analyze the experience with allograft transplantation of the extensor mechanism in total knee arthroplasty and compare results with the international experience.METHODS: We retrospectively evaluated three cases of extensor mechanism allograft after total knee arthroplasty performed in our hospital with the aid of one of the few tissue banks in Brazil and attempt to establish whether our experiences were similar to others reported in the world literature regarding patient indication, techniques, and outcomes.RESULTS: Two cases went well with the adopted procedure, and one case showed bad results and progressed to amputation. As shown in the literature, the adequate tension of the graft, appropriate tibial fixation and especially the adequate patient selection are the better predictors of good outcomes. Previous chronic infection can be an unfavorable predictor. CONCLUSION: This surgical procedure has precise indication, albeit uncommon, either because of the rarity of the problem or because of the low availability of allografts, due to the scarcity of tissue banks in Brazil. Level of Evidence IV, Case Series.


Subject(s)
Humans , Male , Female , Aged, 80 and over , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/rehabilitation , Tissue Banks , Bone Transplantation/adverse effects , Bone Transplantation/rehabilitation , Retrospective Studies
3.
Acta ortop. bras ; 19(1): 41-44, 2011. tab
Article in Portuguese | LILACS | ID: lil-582365

ABSTRACT

OBJETIVO: Análise dos resultados de 159 pacientes com instabilidade anterior do ombro submetidos ao tratamento artroscópico de janeiro de 2001 a dezembro de 2005. MÉTODOS: Estudo retrospectivo de prontuários com dados completos. RESULTADOS: Em 108 pacientes notou-se a lesão de Bankart e em 62 pacientes a lesão do tipo SLAP estava presente. Utilizou-se em média 2,7 âncoras. Apresentaram complicações 42 casos; 14 tinham dor aos esforços, 12 tinham algum grau de diminuição da rotação externa, 16 apresentaram recidiva. Os pacientes que evoluíram com complicações utilizaram em média 2,5 âncoras, enquanto naqueles sem complicações a média foi de 2,8 (p<0,05). De 35 pacientes com lesão óssea da borda anterior da glenóide 8 tiveram recidiva e de 124 casos sem fratura 8 recidivaram (p<0,05). De 113 pacientes com primo-luxação traumática 12 evoluíram com limitação da rotação externa enquanto em 46 casos atraumáticos nenhum apresentou limitação (p<0,05). Dos casos que apresentavam lesão SLAP 11 evoluíram com dor, enquanto que nos casos sem esta lesão três apresentaram dor (p<0,05). CONCLUSÃO: Houve maior índice de recidiva na presença da lesão óssea da borda anterior da glenóide. Dor pós-operatória foi mais frequente quando presente a lesão SLAP. Limitação da rotação externa está relacionada com instabilidade traumática.


OBJECTIVE: To analyze the results of 159 patients with anterior instability of the shoulder submitted to arthroscopic treatment from January 2001 to December 2005. METHODS: Retrospective study of complete patient records. RESULTS: In 108 patients the Bankart lesion was found, while in 62 patients, SLAP type lesions were found. An average of 2.7 anchors was used. 42 cases presented complications; 14 had pain on effort, 12 had some degree of reduction of external rotation, and 16 had recorrence. The patients who developed complications used an average of 2.5 anchors, while those without complications used an average of 2.8 anchors (p<0.05). Of the 35 patients with anterior glenoid bone lesion, 8 had recorrence, while of the 124 patients without fractures, 8 had recorrence (p<0.05). Of the 113 patients with first-time traumatic dislocations, 12 developed limitation of external rotation, while in 46 atraumatic cases none developed limitation (p<0.05). Of the patients with SLAP lesion, 11 developed pain, while in the cases without this lesion, only 3 presented pain (p<0.05). CONCLUSION: There were more recurrences (deveria ser plural e recurrences, nao recurrence) in cases of anterior glenoid bone lesion. Post-operative pain was more frequent when the lesion type was SLAP. Limitation of external rotation is associated to traumatic instability.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Joint Instability , Joint Instability/rehabilitation , Joint Instability , Shoulder Dislocation/diagnosis , Shoulder Dislocation , Shoulder Joint , Brazil , Magnetic Resonance Imaging , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL